Sign In | Join Free | My autoplansearch.com
autoplansearch.com
Products
Search by Category
Wholesale Marketplace
Home > Printing Plate >

600V Electrical Cable Wire BVVB BV Copper Core PVC Insulation Solid Flat Cable

Categories Electrical Cable Wire
Brand Name: JinHong
Model Number: BVVB
Certification: CCC
Place of Origin: Anhui China
MOQ: 100m
Price: 0.12-0.17USD
Payment Terms: T/T
Delivery Time: 5-8
Conductor type: Stranded,Solid,Solid/Flexible
Conductor material: Copper,etc.,Fiberglass with nichrome wire,solid or stranded tinned copper,Copper | Tinned Copper
Application: Heating,Electric conduction,Lights and Lamps,Electric appliance,AWM Appliance Wiring Material
Type: Insulated,Bare
Insulation material: Rubber,PVC,Silicone,fiber glass,XLPE
Color: Requirement,Yellow,can be customized,red black,White/Blue/Red/Black/Brown/Yellow/Green/Transparent
Rated voltage: 600V,300/500V,300/500V 450/750V
Product name: Copper Core PVC Insulation Wire,DIY silicone wire,anchor silicone copper electric wire 220v 3 wire flat cable,silicone rubber electrical wire cable for neon lighting,XLPE Irradiation wire
Conductor: Copper Core,Tinned copper,fiberglass nichrome conductor wire,Stranded Copper,Silver & Tinned & Nickel Copper
Insulation: Silicone Rubber,Silicone insulation,PVC Insulation Cable,PVC,XLPE
Size: Optional,18awg/22awg,30AWG - 4/0AWG,24awg~12awg,2-30
Rated temperature: 200,-60C-+200C,+200℃,-60~ 200,-60'C ~ + 180'C
Packing: 305meters per roll,100m/roll,100 pieces / bag,305/610m per roll,optional
Material: Silicone rubber,silicone wire,High Purity Copper,Tinned copper
Standard: UL758,IEC 60227,GB IEC JIS NEMA,IEC60502
Temperature: 150 degree,-60℃ to 200℃,200degree,-60C~+150C
Length: optional,100mm,Customized Length,610m
Usage: heating element,Indoor,Heating Product
Test voltage: 3000V
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

600V Electrical Cable Wire BVVB BV Copper Core PVC Insulation Solid Flat Cable

BVVB Cable is a Flat Sheathed PVC Insulated and Sheathed Copper Wire, designed for fixed electrical installations where
space-saving and compact routing are required. The name BVVB breaks down as follows:
* B: Insulated Wiring (Chinese standard designation)
* V: PVC Insulation
* V: PVC Sheath
* B: Flat Type

Applications
* Building Wiring: Fixed electrical circuits in residential and commercial buildings, especially for surface mounting.
* Lighting Systems: Wiring for lighting fixtures and decorative lighting.
* Power Distribution: Connections for appliances, outlets, and switches.
* Temporary Installations: Exhibition wiring and temporary power supply (with additional protection).
Why Choose BVVB Cable?
* Space-Saving Design: Flat structure allows for compact routing and easy surface mounting.
* Easy to Install: Pre-assembled parallel conductors simplify installation.
* Cost-Effective: Affordable solution for fixed electrical installations.
* Aesthetic Appeal: Neat and tidy appearance for exposed wiring applications.
BVVB cable is ideal for surface-mounted fixed wiring applications. For flexible needs, consider BVR (flexible copper conductor),or for enhanced fire safety, NH-BVVB (fire-resistant). Customizable conductor sizes (e.g., 2×1.5 mm² to 3×6 mm²) are available Consult technical datasheets for details.
Selection Guidelines
For Lighting Circuits:
* General Lighting: 2×1.5 mm², 300/500V
* Decorative Lighting: 2×0.75 mm², 300/300V
* Commercial Lighting: 2×2.5 mm², 300/500V
For Power Outlets:
* General Sockets: 2×2.5 mm², 300/500V
* Kitchen Appliances: 3×2.5 mm², 450/750V
* Air Conditioners: 3×4 mm², 450/750V
For Special Applications:
* Control Circuits: 2×1.5 mm², 300/300V
* Equipment Power: 3×6 mm², 450/750V
* Industrial Use: 3×10 mm², 450/750V
Nominal section(mm²)Number/diameter of core(mm)Maximum outer diameter(mm)Reference weight(kg/km)Conductor resistance at 20℃(Ω/km)
2x0.752×1/0.974.8×7.043.7-
2x1.02×1/1.134.8×7.451.0-
2x1.52×1/1.385.4×8.465.9-
2x2.52×1/1.786.2×9.895.77.41
2x42×7/0.857.2×11.5146.04.61
2x62×7/1.048.0×13.0200.03.08
2x102×7/1.359.6×16.0323.01.83
2x0.753×1/0.974.6×9.462.624.50
2x1.03×1/1.134.8×9.874.318.10
3x1.53×1/1.385.4×11.595.612.10
3x2.53×1/1.786.2×13.51407.41
3x43×7/0.857.4×16.52207.41
3x63×7/1.048.0×18.02954.61
3x103×7/1.359.6×22.54851.83
FAQ:
1. What does BVVB stand for?
* B: Fixed wiring cable (Chinese standard classification)
* V: PVC insulation
* V: PVC sheath
* B: Flat type design
BVVB is a flat-type PVC insulated and sheathed copper cable designed for fixed electrical installations where space-saving and surface mounting are required.
----------------------------------------------------------------------------------------------------------------------------------

2. What are the standard voltage ratings for BVVB cable?
* 300/300V: For low-voltage lighting and signal circuits
* 300/500V: Most common for residential and commercial applications
* 450/750V: For higher power applications and industrial use
* Special Versions: 250/440V for specific markets, 600/1000V for industrial applications
----------------------------------------------------------------------------------------------------------------------------------

3. Where is BVVB cable typically used?
* Residential buildings: Surface-mounted wiring for sockets and lighting
* Commercial spaces: Office power distribution, retail store installations
* Renovation projects: Retrofitting existing buildings without concealed conduits
* Temporary installations: Exhibition booths, stage wiring, construction sites
* Furniture manufacturing: Built-in electrical systems for cabinets and displays
----------------------------------------------------------------------------------------------------------------------------------

4. What is the temperature rating of BVVB cable?
* Normal operating temperature: -15°C to +70°C
* Maximum conductor temperature: 70°C continuous operation
* Short-circuit withstand: 160°C for maximum 5 seconds
* Installation temperature: Minimum 0°C to prevent sheath damage

5. What safety standards does BVVB comply with?
* International: IEC 60227
* Chinese National: GB/T 5023
* Certifications: CCC (China Compulsory Certification), CE marking
* Fire Performance: Standard version has basic flame retardancy (for enhanced safety, choose ZR-BVVB)
----------------------------------------------------------------------------------------------------------------------------------

6. Can BVVB be used outdoors or in wet locations?
* Not recommended for direct outdoor exposure
* Suitable for indoor dry locations only
* Requires additional protection (conduits, trunking) in damp areas
* Not designed for direct burial or prolonged moisture exposure
---------------------------------------------------------------------------------------------------------------------------------

7. What are the available conductor configurations?
* 2-core: For basic lighting and socket circuits
* 3-core: For grounded applications and three-phase systems
* Conductor Sizes: 0.75 mm² to 10 mm² per core
* Common Combinations: 2×1.5 mm², 2×2.5 mm², 3×1.5 mm², 3×2.5 mm²
----------------------------------------------------------------------------------------------------------------------------------
8. What is the current carrying capacity of BVVB?
Examples for 300/500V BVVB:
* 2×1.5 mm²: 16-20A (depending on installation method)
* 2×2.5 mm²: 20-27A
* 3×1.5 mm²: 14-18A
* 3×2.5 mm²: 18-25A
Note: Actual capacity varies with installation conditions and local regulations
----------------------------------------------------------------------------------------------------------------------------------

9. What are the main advantages of BVVB cable?
* Space Efficiency: Flat design saves space in shallow installations
* Easy Installation: Pre-arranged conductors simplify wiring
* Aesthetic Appeal: Neat appearance for surface-mounted applications
* Cost-Effective: Economical solution for basic power and lighting circuits
* Time Saving: Faster installation compared to separate round cables
----------------------------------------------------------------------------------------------------------------------------------

10.How should BVVB be installed and supported?
* Fixing Methods: Use flat cable clips or adhesive channels
* Support Spacing: Every 30-50 cm for horizontal runs
* Bending Radius: Minimum 6× cable width
* Protection: Additional conduits in high-traffic areas
* Separation: Maintain distance from heat sources and sharp edges

BV :Rigid wire,a single-core copper wire.
BVR: Flexible wire, a single-core wire made of multiple copper strands twisted together
RV: Also a flexible wire, a single-core wire made of multiple copper strands twistedtogether, generally not used for home
decoration.
BVVB: Rigid sheathed wire, two or more BV wires sheathed together
RVVB: Flexible sheathed wire, two, three, or four RV wires sheathed together.

Quality 600V Electrical Cable Wire BVVB BV Copper Core PVC Insulation Solid Flat Cable wholesale
Send your message to this supplier
 
*From:
*To: JinHong Wire And Cable Group
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0