Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent

Categories Molded Case Circuit Breaker
Brand Name: Winston/OEM
Model Number: WCM1
Certification: CE,ROSH
Place of Origin: China,Zhejiang
MOQ: 1PCS
Price: USD10 to USD450/PCS
Payment Terms: T/T,L/C,Paypal,Online Payment,RMB/USD
Supply Ability: 10000PCS/Month
Delivery Time: 3-15days after get payment.
Packaging Details: Export standard carton box
Material: Plastic
Current: from 6A to 1600A
Poles: 3,4
Frequency: 50/60HZ
Rated operating voltage: 400V or below
OEM: Yes
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent

    Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent


    WCM1 series moulded case circuit breaker is one of products developed and manufactured by adopting international advanced technology. It is supplied with rated insulating voltage 550 and 800V and used for circuit of AC 50/60Hz, rated operating voltage AC 400V (or below), rated operating current up to 1600A for infrequent changing over and starting of the motors.The products conforms to IEC60947-2 standard.

    TECHNICAL PARAMETER

    Main Technical Specification(table1)

    Type

    Rated
    current (A)

    Polenum-ber

    Ratedinsui-atingvolt-age(V)

    Rated
    operat-ingvolt-age(V)

    Arcing-
    over
    distance
    (mm)

    Ultimate
    short
    circuit
    breaking
    capacity
    (KA)

    Servies
    short
    circuit
    breaking
    capacity
    (KA)

    Operation
    perform-
    ance

    Utiliza-tioncat-egory

    Load

    Unload

    WCM1-63L

    (6),10
    16,20
    25 ,32
    40,50
    63

    3, 4

    500V

    400V

    0

    25

    18

    1500

    8500

    A

    WCM1-63M

    0

    50

    35

    WCM1-100L

    (10),16
    20,25
    32,40
    50,63
    80,100

    800V

    0(≤50)

    35

    22

    WCM1-100M

    0(≤50)

    50

    35

    WCM1-100H

    0(≤50)

    85

    50

    1000

    7000

    WCM1-225L

    100,125
    160,180
    200,225

    ≤50

    35

    22

    WCM1-225M

    ≤50

    50

    35

    WCM1-225H

    ≤50

    85

    50

    1000

    4000

    WCM1-400L

    225,250
    315,350
    400

    ≤50

    50

    35

    WCM1-400M

    ≤100

    65

    42

    WCM1-630L

    400,500
    630

    ≤100

    50

    35

    WCM1-630M

    ≤100

    65

    42

    WCM1-630H

    ≤100

    100

    65

    WCM1-800M

    630,700
    800

    3

    ≤100

    75

    50

    WCM1-800H

    ≤100

    100

    65

    WCM1-1250M

    1000,1250

    ≤100

    100

    65

    WCM1-1250H

    ≤100

    125

    75

    WCM1-1600M

    1600

    ≤100

    150

    80


    Note: 6A without thermal protection
    The N-pole of four-poles breaker is sited at the right side of the product has four types:
    Type A: Without current trip-lease on N pole which making all the time, not closing and opening with the other three poles.
    Type B: Without current trip-release on N pole which closing and opening with the other poles.
    Type C: With current trip-release which closing and opening with the other three poles.
    Type D: With current trip-release which making all the time not closing and opening with the other three poles.

    Protection Characteristic
    The thermodynamic release of a circuit breaker provides the feature of inverse time-delay, while the magnetic release is the instantaneous operation as shown on table 2(distribution circuit breaker) and table 3 (motor protection circuit breaker).


    Table2

    Rated current of release (A)

    Thermodynamic release( ambient temperature ) land +40°C marine +45°C

    Operating current of magnetic release (A)

    1.05In(cold state) Inoperative time(h)

    1.30In(heat state) Operative time(h)

    10≤In≤63

    ≥ 1

    < 1

    10In±20%

    63

    ≥ 2

    < 2

    100≤In≤800

    ≥ 2

    < 2

    5In±20% 10In±20%



    Table3

    Rated current

    Thermodynamic release ( ambient temperature ) land +40°C marine +45°C

    Operating current of magnetic release (A)

    of release (A)

    1.0In(cold state) non-trip time(h)

    1.20In(heat state) trip time (h)

    1.50In(heat state) trip time (h)

    7.2In(cold state) trip time(h)

    10 ≤ In ≤ 225

    ≥ 2

    <2

    ≤ 4min

    4s < Tp ≤ 10s

    12In±20%

    225 ≤ In ≤ 630

    ≤ 8min

    6s < Tp ≤ 20s



    Accessories of Circuit breaker
    1 The external accessories of the breaker
    Motor-driven operation device
    1) Wiring diagram of type CDM electromagnetic operation device(fitting AM1-63,100,225) seethe following drawing (wiring diagram of the external accessories of the breaker in the dotted frame)



    Code description: SB1SB2stand for push button.(provided by users themselves) Number "1" "2" "3" stand for number of wiring terminals.
    Voltage rating: AC50Hz 230V 400V DC 220V
    2) Wiring diagram of type CD motor-driven operation device (fitting AM1-400 630 800) seebelows (wiring diagram of the external accessories of the breaker in the dotted frame)




    Code description: SB1SB2stand for push button. (provided by users themselves) "X" stands for line connection terminals
    Voltage rating: AC50Hz 230V 400V DC 220V



    Rotary handle operation device
    The mechanism is used in moulded case circuit breaker to operate the draw-out panel. Powerdistribution panel and supply box outside the panel by turning the handle ,and to ensure thedoor of panel would not be openned when the breaker being on. The hand-drive mechanism can be equiped with two types of operation, one is "A" modelsquare handle , the other is "B" model round handle.



    4.2 Release pattern and accessories code

    SHT: Shunt release; UVR: Under-voltage release;AX: Auxiliary contact; AL: Alarm contact

    Release patternand accessories codeName/TypeWCM1-63,
    100, 225
    WCM1-400WCM1-630WCM1-800
    200, 300No accessories200: magnetic release (only short circuit protection)300: thermal magnetic release(both overload and short circuit protection)
    208, 308Alarm contact
    210, 310Shunt release
    220, 320Auxiliary contact
    230, 330Under-voltage release
    240, 340Shunt release
    Auxiliary contact
    250, 350Shunt release
    Under-voltage release
    260, 360Two group of auxiliary contact
    270,370Under-voltage release
    Auxiliary contact
    218, 318Shunt release
    Alarm contact
    228, 328Alarm contact Auxiliary contact
    238, 338Under-voltage releaseAlarm contact
    248, 348Shunt release, Alarm contact,Auxiliary contact
    268, 368Two group of auxiliary contact,Alarm contact
    278, 378Shunt release, Alarm contact, Under-voltage release


    According to user's demands, accessories could lead to direct wire outcoming or line wiringterminals could be added(please mark out in case of making order).

    Under-voltage release
    Wring diagram of the under-voltage module connected externally (the internal accessories inthe dotted frame)Ue: AC50Hz 230V, 400V



    When the operation voltage is 35%~70% of the rated voltage, the under-voltage release shouldmake the breaker trip correctly.When the operation voltage is 85%~110% of the rated voltage, the under-voltage release shouldmake the breaker close.In case of the operation voltage less than 35% of the rated voltage, the under-voltage shouldprevent the breaker from closing.Note: Only the under-voltage release should be energized in advanced, the breaker could berecramped and turned-on, otherwise the breaker will be damaged.


    Shunt release
    Scheme of wiring(the internal accessories in the dotted frame)"K" is the slow motion switch normal-close contact connect the coil in series in the shunt release.It turns-on or turns-off voluntarily as soon as the breaker on or off.



    Voltage rating: AC50Hz 230V or 400V, DC 110V 220VThe shunt release should make the breaker trip reliably when the operation voltage is 70%~110%of the rated control voltage.

    Alarm contact
    The position of the breaker in "off" or "on"
    The position of the breaker in "free trip" (alarm)
    B11 and B12 switch from "close" to "open", statusof B11 and B14 switch from "open" to "close"


    Auxiliary Contact
    When the breaker is in"off"For the breaker with frame current400A and above
    For the breaker with frame current225A and below
    When the breaker is in"on"When the breaker is in "off", the contacts switch from "close" to "open".When the breaker is in "off",the contacts switch from "open"to close"

    Quality Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent wholesale
    Send your message to this supplier
     
    *From:
    *To: YUEQING WINSTON ELECTRIC CO.,LTD.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0

    Friendly Links: www.everychina.com

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

    Copyright © 2009 - 2024 autoplansearch.com. All rights reserved.