SAE-J 1128-2005 11-2008 Fire Testing Equipment Vertical Flammability Tester For Wire / Cable

Categories Fire Testing Equipment
Brand Name: SKYLINE
Model Number: SL-S28
Certification: QC/T703-2005,SAE-J 1128-2005
Place of Origin: China
MOQ: 1 unit
Price: neogitable
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 1 unit / month
Delivery Time: 10 work days
Packaging Details: plywood case
SKYLINE: Automotive Wires Flammability Testing Equipment
Standards: GB/T18380.1-2008,GB/T18380.11-2008,GB/T18380.12-2008
Ignition time: 0.1s can be set
Dimension: 60 x 45 x 156cm(L*W*H)
Burner: inner diameter Φ9.5mm ± 0.5mm
Flame Height: 20mm ± 2mm to 190mm±1mm
Air Flow: 1.5-15L/min
Length of cable to be tested: 600±25mm
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    SAE-J 1128-2005 11-2008 Fire Testing Equipment Vertical Flammability Tester For Wire / Cable

    SAE-J 1128-2005 Vertical Flammability Tester for Wire / Cable 600 ± 25mm Length


    Application

    Single wire / cable vertical combustion tester mainly for the conductor diameter greater than 8mm (section area is greater than 0.5mm2) or less than 8mm (section area less than 0.5mm2) of single wire and cable flammability evaluation. Suitable for lighting equipment, low-voltage electrical appliances, household appliances, electrical tools, electric motor, electric tools, electronic instruments, electrical instruments, electrical connectors and accessories such as electrical and electronic products and components of the research, production and quality inspection department. This section adopts the recommended product structure of the air mixing structure in Appendix B of GB18380.12-2008, and also meets the requirements of the quality inspection unit in detail.


    Technical parameters

    1.Seven inch full-color programmable controller, touch screen, +PLC control, to achieve control / detection / calculation / data display multi-function.

    2.A high degree of automation: automatic record test time, automatic test results, automatic timing, automatic ignition, flame after the end of the Bunsen burner automatically returned, you can choose whether or not to shut off gas.
    3.When you start, you can choose whether to auto ignition, start, stop, gas, timing, ignition, preservation, preservation, lighting, exhaust control by touch screen control, fingertips touch, you can complete the test.
    4. Timing button, with PLC automatic recording, storage, burning time.
    5. Test time system automatically record and produce test results.
    6. Burner: inner diameter Phi 9.5mm + 0.5mm.
    7. Test tilt angle: 45 degrees, the beam can move back and forth, according to the pattern thickness adjustment and Bunsen lamp position.
    8. Flame height: 20mm + 2mm to 190mm + 1mm adjustable.
    9. Flame time: 0-999.9s + 0.1s adjustable.
    10.Combustion gas: 95% propane gas (in general can use liquefied petroleum gas instead).
    11. Gas: using high purity propane gas or liquefied petroleum gas (user owned).
    12. Tested wire and cable length: 600 + 25mm.
    13. Tested wire and cable diameter: conductor diameter greater than 0.8mm or cross-sectional area greater than 0.5mm2.
    14.The device should be placed in the wind, and the temperature is (23 + 10) Celsius in the environment for testing.
    15. Standard combustion burner power: 1KW.
    16. Power supply voltage: 220V/50Hz.
    17. Gas flow: 0-1L/min.
    18. Air flow: 1.5-15L/min.
    19. Box material: steel plate electrostatic spraying (stainless steel case can be specified).
    20.Equipment size: 60 cm long, 45cm wide, 156cm high.


    Features

    Single cable vertical burning test is set by size Bunsen (Bunsen burner) and the specific gas source (Bing Wan), according to a certain flame height and some application of flame angle on the vertical state of the sample application to test ignition timing, ignition, combustion duration and combustion to assess its length flammable and fire hazard.


    Quality SAE-J 1128-2005 11-2008 Fire Testing Equipment Vertical Flammability Tester For Wire / Cable wholesale
    Send your message to this supplier
     
    *From:
    *To: SKYLINE INSTRUMENTS CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0

    Friendly Links: www.everychina.com

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

    Copyright © 2009 - 2024 autoplansearch.com. All rights reserved.